$1,612.00 – $2,711.00Price range: $1,612.00 through $2,711.00
- Continuous UV monitoring in addition to lamp status monitoring
- System diagnostics and potential fault codes
- Colour interface for easy visual identification of UV intensity
- Future proof expandability port
- Lamp key for 100% protected UV lamp sales
- Constant current electronic power source
- Housed in splash proof case with “future proof” expandability
Luminar Blackcomb 6.1 Monitored High Output UV Water Treatment System
For higher flow rates, consider LUMINOR’s BLACKCOMB-HO 6.1 line of “Residential Crossover” UV water treatment systems.
Installed in a large residence or in a light commercial application, continuous UV water quality monitoring is provided by the inclusion of a true 254nm discrete UV monitor. Using Teflon technology for reduced fouling, these sensors allow for the addition of a solenoid shut-off valve and a 4-20mA output allowing for remote monitoring or data logging.
A colour user interface allows for easy visual identification of UV intensity, remaining lamp life and any error or fault codes as well as a monitoring of a full system diagnostic on start-up. The system also incorporates QR codes to access lamp change information and videos via web access. The controller’s universal input, constant current electronic power source is housed in a splash-proof case and comes standard with a “future-proof” expandability port for future upgrades or options.
Commercial grade axial flow 316L stainless steel, single-end reactors allow for lamp change without the need to drain the reactor chamber. Low pressure, high-output (LP-HO) coated UV lamps offer a consistent output over their 10,000 hour rated life and come paired with LUMINOR’s encrypted lamp key technology to protect against improper use.
Flow rates of 15, 38, 53, 95 & 150 lpm (5, 10, 15, 25 & 40 gpm), in both 120V or 230V applications (same UV ballast, different IEC power cord), are offered in the BLACKCOMB-HO 6.1 series of products.
| Model | Flow Rate | LBH6-05, LBH6-10, LBH6-15, LBH6-25, LBH6-40 |
|---|---|
| Application | Standard, Hot Water, Low UVT, TOC |
| Brand | Luminor |
Specs
Regular
| Model | LBH6-051 | LBH6-101 | LBH6-151 | LBH6-251 | LBH6-401 |
|---|---|---|---|---|---|
| Flow Rate @ 16 mJ/cm²* (US Public Health) |
8.0 gpm | 19 gpm | 27 gpm | 47 gpm | 78 gpm |
| 30 lpm | 72 lpm | 100 lpm | 180 lpm | 290 lpm | |
| 1.8 m³/hr | 4.3 m³/hr | 6.1 m³/hr | 11 m³/hr | 18 m³/hr | |
| Flow Rate 30 mJ/cm²* (Industry Std.) |
4.0 gpm | 10 gpm | 14 gpm | 25 gpm | 40 gpm |
| 15 lpm | 38 lpm | 53 lpm | 95 lpm | 150 lpm | |
| 1.1 m³/hr | 2.3 m³/hr | 3.2 m³/hr | 5.7 m³/hr | 9.1 m³/hr | |
| Flow Rate @ 40 mJ/cm²* |
3.0 gpm | 7.0 gpm | 11 gpm | 19 gpm | 31 gpm |
| 15 lpm | 38 lpm | 53 lpm | 72 lpm | 120 lpm | |
| 0.7 m³/hr | 1.6 m³/hr | 2.5 m³/hr | 4.3 m³/hr | 7.0 m³/hr | |
| Port Size | ½” MNPT | ¾” MNPT | 1″ MNPT | 1″ MNPT | 1½” MNPT |
| Electrical | 90-265V / 50-60Hz | ||||
| Plug Type | American: Nema 5/15 – “1” suffix (i.e. LBH6-101) European: CEE 7/7 – “2” suffix (i.e. LBH6-102) British Standard: BS 1363 – “3” suffix (i.e. LBH6-103) Australian/New Zealand: AS/NZ 3112 – “4” suffix (i.e. LBH6-104) |
||||
| Lamp Watts | 18 | 34 | 45 | 67 | 101 |
| Power (watts) | 20 | 38 | 57 | 73 | 115 |
| Chamber Material | 316L Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated | ||||
| Replacement Lamp | RL-210HO | RL-330HO | RL-420HO | RL-600HO | RL-950HO |
| Replacement Sleeve | RQ-210 | RQ-330 | RQ-420 | RQ-600 | RQ-950 |
| Reactor Dimensions | 3.5 x 11.7″ (8.9 x 29.8 cm) |
3.5 x 16.5″ (8.9 x 41.8 cm) |
3.5 x 20.0″ (8.9 x 50.8 cm) |
3.5 x 26.9″ (8.9 x 68.3 cm) |
3.5 x 40.7″ (8.9 x 103.4 cm) |
| Controller Dimensions | 8.6 x 4.2 x 4″ (217.4 x 107.5 x 102 mm) | ||||
| Maximum Operating Pressure | 10.3 bar (150 psi) | ||||
| Operating Temperature Range | 2-40° C (36-104° F) | ||||
| UV Monitor | Yes | ||||
| Dry Contacts (solenoid ready) | Optional | ||||
| 4-20 mA Output | Optional | ||||
| Lamp Age Counter | Yes | ||||
| Lamp-Out Indicator (audible & visual) | Yes | ||||
| Shipping Weight | 4.5 kg (9.9 lbs) | 5.4 kg (11.9 lbs) | 6.0 kg (13.2 lbs) | 7.3 kg (16.1 lbs) | 9.8 kg (21.6 lbs) |
| *Note: | Flow rate for a given dose is calculated based on system output at end of lamp life in water with 95% UVT | ||||
Hot Water
| Model | LBH6-151-HW | LBH6-251-HW | LBH6-401-HW |
|---|---|---|---|
| Flow Rate 30 mJ/cm² @ 75% UVT (Industry Std.) |
10 gpm | 17 gpm | 29 gpm |
| 39 lpm | 65 lpm | 110 lpm | |
| 2.3 m³/hr | 3.9 m³/hr | 6.6 m³/hr | |
| Port Size | 1″ MNPT | 1″ MNPT | 1½” MNPT |
| Electrical | 90-265V / 50-60Hz | ||
| Plug Type | American: Nema 5/15 – “1” suffix (i.e. LBH6-151-HW) European: CEE 7/7 – “2” suffix (i.e. LBH6-152-HW) British Standard: BS 1363 – “3” suffix (i.e. LBH6-153-HW) Australian/New Zealand: AS/NZ 3112 – “4” suffix (i.e. LBH6-154-HW) |
||
| Lamp Watts | 45 | 67 | 101 |
| Power (watts) | 57 | 73 | 115 |
| Chamber Material | 316L Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated | ||
| Replacement Lamp | RL-420HW | RL-600HW | RL-950HW |
| Replacement Sleeve | RQ-420 | RQ-600 | RQ-950 |
| Reactor Dimensions | 3.5 x 20.0″ (8.9 x 50.8 cm) |
3.5 x 26.9″ (8.9 x 68.3 cm) |
3.5 x 40.7″ (8.9 x 103.4 cm) |
| Controller Dimensions | 8.6 x 4.2 x 4″ (217.4 x 107.5 x 102 mm) | ||
| Maximum Operating Pressure | 10.3 bar (150 psi) | ||
| Operating Temperature Range | 2-65° C (36-149° F) | ||
| UV Monitor | Yes | ||
| Dry Contacts (solenoid ready) | Optional | ||
| 4-20 mA Output | Optional | ||
| Lamp Age Counter | Yes | ||
| Lamp-Out Indicator (audible & visual) | Yes | ||
| Shipping Weight | 6.0 kg (13.2 lbs) | 7.3 kg (16.1 lbs) | 9.8 kg (21.6 lbs) |
Low UVT
| Model | LBH6-051-50 | LBH6-101-50 | LBH6-151-50 | LBH6-251-50 | LBH6-401-50 |
|---|---|---|---|---|---|
| Flow Rate 30 mJ/cm² @ 50% UVT (Industry Std.) |
2.0 gpm | 4.5 gpm | 6.2 gpm | 10 gpm | 17 gpm |
| 8.0 lpm | 17 lpm | 23 lpm | 39 lpm | 66 lpm | |
| 0.45 m³/hr | 1.0 m³/hr | 1.4 m³/hr | 2.3 m³/hr | 4.0 m³/hr | |
| Port Size | ½” MNPT | ¾” MNPT | 1″ MNPT | 1″ MNPT | 1½” MNPT |
| Electrical | 90-265V / 50-60Hz | ||||
| Plug Type | American: Nema 5/15 – “1” suffix (i.e. LBH6-101-50) European: CEE 7/7 – “2” suffix (i.e. LBH6-102-50) British Standard: BS 1363 – “3” suffix (i.e. LBH6-103-50) Australian/New Zealand: AS/NZ 3112 – “4” suffix (i.e. LBH6-104-50) |
||||
| Lamp Watts | 18 | 34 | 45 | 67 | 101 |
| Power (watts) | 20 | 38 | 57 | 73 | 115 |
| Chamber Material | 316L Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated | ||||
| Replacement Lamp | RL-210HO | RL-330HO | RL-420HO | RL-600HO | RL-950HO |
| Replacement Sleeve | RQ-210 | RQ-330 | RQ-420 | RQ-600 | RQ-950 |
| Reactor Dimensions | 3.5 x 11.7″ (8.9 x 29.8 cm) |
3.5 x 16.5″ (8.9 x 41.8 cm) |
3.5 x 20.0″ (8.9 x 50.8 cm) |
3.5 x 26.9″ (8.9 x 68.3 cm) |
3.5 x 40.7″ (8.9 x 103.4 cm) |
| Controller Dimensions | 8.6 x 4.2 x 4″ (217.4 x 107.5 x 102 mm) | ||||
| Maximum Operating Pressure | 10.3 bar (150 psi) | ||||
| Operating Temperature Range | 2-40° C (36-104° F) | ||||
| UV Monitor | Yes | ||||
| Dry Contacts (solenoid ready) | Optional | ||||
| 4-20 mA Output | Optional | ||||
| Lamp Age Counter | Yes | ||||
| Lamp-Out Indicator (audible & visual) | Yes | ||||
| Shipping Weight | 4.5 kg (9.9 lbs) | 5.4 kg (11.9 lbs) | 6.0 kg (13.2 lbs) | 7.3 kg (16.1 lbs) | 9.8 kg (21.6 lbs) |
TOC
| Model | LBH6-151-TOC | LBH6-251-TOC | LBH6-401-TOC |
|---|---|---|---|
| Flow Rate 150 mJ/cm² @ 95% UVT (Industry Std.) |
3.0 gpm | 5.0 gpm | 8.5 gpm |
| 11 lpm | 19 lpm | 32 lpm | |
| 0.68 m³/hr | 1.1 m³/hr | 1.9 m³/hr | |
| Port Size | 1″ MNPT | 1″ MNPT | 1½” MNPT |
| Electrical | 90-265V / 50-60Hz | ||
| Plug Type | American: Nema 5/15 – “1” suffix (i.e. LBH6-151-TOC) European: CEE 7/7 – “2” suffix (i.e. LBH6-152-TOC) British Standard: BS 1363 – “3” suffix (i.e. LBH6-153-TOC) Australian/New Zealand: AS/NZ 3112 – “4” suffix (i.e. LBH6-154-TOC) |
||
| Lamp Watts | 45 | 67 | 101 |
| Power (watts) | 57 | 73 | 115 |
| Chamber Material | 316L Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated | ||
| Replacement Lamp | RL-420HO-TOC | RL-600HO-TOC | RL-950HO-TOC |
| Replacement Sleeve | RQ-420 | RQ-600 | RQ-950 |
| Reactor Dimensions | 3.5 x 20.0″ (8.9 x 50.8 cm) |
3.5 x 26.9″ (8.9 x 68.3 cm) |
3.5 x 40.7″ (8.9 x 103.4 cm) |
| Controller Dimensions | 8.6 x 4.2 x 4″ (217.4 x 107.5 x 102 mm) | ||
| Maximum Operating Pressure | 10.3 bar (150 psi) | ||
| Operating Temperature Range | 2-40° C (36-104° F) | ||
| UV Monitor | Yes | ||
| Dry Contacts (solenoid ready) | Optional | ||
| 4-20 mA Output | Optional | ||
| Lamp Age Counter | Yes | ||
| Lamp-Out Indicator (audible & visual) | Yes | ||
| Shipping Weight | 6.0 kg (13.2 lbs) | 7.3 kg (16.1 lbs) | 9.8 kg (21.6 lbs) |
Only logged in customers who have purchased this product may leave a review.
Related products
Luminor Blackcomb 4.1 High Output UV Water Treatment System
In stock
Luminor Blackcomb 5.1 High Output UV Water Treatment System
In stock
Luminor Blackcomb 5.1 UV Water Treatment System
In stock
Luminor Blackcomb 6.1 Monitored UV Water Treatment System
In stock

Reviews
Clear filtersThere are no reviews yet.