Luminor Blackcomb 5.1 High Output UV Water Treatment System
- Entry level price point with built-in UV lamp countdown timer and total elapsed running time readouts
- Tactile button selector
- Thermally-managed, fully potted, watertight case
- Manual UV lamp reset feature
- Separate 120V or 230V plug configuration
$1,079.00 – $2,157.00
- Pick up from the Yachtmate Store
Pickup available on some items. Call us to confirm availability.
Call Us
- Standard Shipping
Standard ground shipping through service of our choice.
3-5 Days
Free Shipping Over $100
- Freight Shipping
Large freight shipping through service of our choice or arranged by you.
5-7 Days
Call for Quote
- Manufacturer Warranty
- No-Hassle Returns on Defective Products
Payment Methods:
Luminar Blackcomb 5.1 High Output UV Water Treatment System
Looking for a comprehensive UV system in higher flow rates, consider LUMINOR’s BLACKCOMB-HO 5.1 line of “Residential Crossover” UV water treatment systems.
The BLACKCOMB-HO 5.1 models can be installed in a large custom residence or a light commercial application such as a campground. BLACKCOMB-HO’s 5.1 series controller is a universal input, constant current electronic power source housed in a splash-proof case and comes standard with a “future-proof” expandability port for future upgrades or options.
A colour user interface allows for easy visual identification of remaining lamp life and any error or fault codes. The system also incorporates QR codes to access lamp change information and videos via web access. Commercial grade axial flow 316L stainless steel, single-end reactors come with an integral port to allow for a future upgrade to a UV monitored system. If a monitor is not required, an integral visual glow plug is provided as an extra way to ensure that your UV lamp is illuminated. The single-end design allows for lamp change without the need to drain the reactor chamber. Low pressure, high-output (LP-HO) coated UV lamps offer a consistent output over their 10,000 hour rated life and come paired with LUMINOR’s encrypted lamp key to protect against improper use.
Flow rates of 15, 38, 59, 95 & 150 lpm (5, 10, 15, 25 & 40 gpm), in both 120V or 230V applications (same ballast, different IEC power cord), are offered in the BLACKCOMB-HOÂ 5.1Â series of products.
Specs
Regular
Model | LBH5-051 | LBH5-101 | LBH5-151 | LBH5-251 | LBH5-401 |
---|---|---|---|---|---|
Flow Rate @ 16 mJ/cm²* (US Public Health) |
8.0 gpm | 19 gpm | 27 gpm | 47 gpm | 78 gpm |
30 lpm | 72 lpm | 100 lpm | 180 lpm | 290 lpm | |
1.8 m³/hr | 4.3 m³/hr | 6.1 m³/hr | 11 m³/hr | 18 m³/hr | |
Flow Rate 30 mJ/cm²* (Industry Std.) |
4.0 gpm | 10 gpm | 14 gpm | 25 gpm | 40 gpm |
15 lpm | 38 lpm | 53 lpm | 95 lpm | 150 lpm | |
1.1 m³/hr | 2.3 m³/hr | 3.2 m³/hr | 5.7 m³/hr | 9.1 m³/hr | |
Flow Rate @ 40 mJ/cm²* |
3.0 gpm | 7.0 gpm | 11 gpm | 19 gpm | 31 gpm |
15 lpm | 38 lpm | 53 lpm | 72 lpm | 120 lpm | |
0.7 m³/hr | 1.6 m³/hr | 2.5 m³/hr | 4.3 m³/hr | 7.0 m³/hr | |
Port Size | ½” MNPT | ¾” MNPT | 1″ MNPT | 1″ MNPT | 1½” MNPT |
Electrical | 90-265V / 50-60Hz | ||||
Plug Type | American: Nema 5/15 – “1” suffix (i.e. LBH5-101) European: CEE 7/7 – “2” suffix (i.e. LBH5-102) British Standard: BS 1363 – “3” suffix (i.e. LBH5-103) Australian/New Zealand: AS/NZ 3112 – “4” suffix (i.e. LBH5-104) |
||||
Lamp Watts | 18 | 34 | 45 | 67 | 101 |
Power (watts) | 20 | 38 | 57 | 73 | 115 |
Chamber Material | 316L Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated | ||||
Replacement Lamp | RL-210HO | RL-330HO | RL-420HO | RL-600HO | RL-950HO |
Replacement Sleeve | RQ-210 | RQ-330 | RQ-420 | RQ-600 | RQ-950 |
Reactor Dimensions | 3.5 x 11.7″ (8.9 x 29.8 cm) |
3.5 x 16.5″ (8.9 x 41.8 cm) |
3.5 x 20.0″ (8.9 x 50.8 cm) |
3.5 x 26.9″ (8.9 x 68.3 cm) |
3.5 x 40.7″ (8.9 x 103.4 cm) |
Controller Dimensions | 8.6 x 4.2 x 4″ (217.4 x 107.5 x 102 mm) | ||||
Maximum Operating Pressure | 10.3 bar (150 psi) | ||||
Operating Temperature Range | 2-40° C (36-104° F) | ||||
UV Monitor | Upgradeable, includes visual glow plug | ||||
Dry Contacts (solenoid ready) | Optional | ||||
4-20 mA Output | Optional | ||||
Lamp Age Counter | Yes | ||||
Lamp-Out Indicator (audible & visual) | Yes | ||||
Shipping Weight | 4.5 kg (9.9 lbs) | 5.4 kg (11.9 lbs) | 6.0 kg (13.2 lbs) | 7.2 kg (15.9 lbs) | 9.7 kg (21.4 lbs) |
*Note: | Flow rate for a given dose is calculated based on system output at end of lamp life in water with 95% UVT |
Hot Water
Model | LBH5-151-HW | LBH5-251-HW | LBH5-401-HW |
---|---|---|---|
Flow Rate 30 mJ/cm² @ 75% UVT (Industry Std.) |
10 gpm | 17 gpm | 29 gpm |
39 lpm | 65 lpm | 110 lpm | |
2.3 m³/hr | 3.9 m³/hr | 6.6 m³/hr | |
Port Size | 1″ MNPT | 1″ MNPT | 1½” MNPT |
Electrical | 90-265V / 50-60Hz | ||
Plug Type | American: Nema 5/15 – “1” suffix (i.e. LBH5-151-HW) European: CEE 7/7 – “2” suffix (i.e. LBH5-152-HW) British Standard: BS 1363 – “3” suffix (i.e. LBH5-153-HW) Australian/New Zealand: AS/NZ 3112 – “4” suffix (i.e. LBH5-154-HW) |
||
Lamp Watts | 45 | 67 | 101 |
Power (watts) | 57 | 73 | 115 |
Chamber Material | 316L Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated | ||
Replacement Lamp | RL-420HW | RL-600HW | RL-950HW |
Replacement Sleeve | RQ-420 | RQ-600 | RQ-950 |
Reactor Dimensions | 3.5 x 20.0″ (8.9 x 50.8 cm) |
3.5 x 26.9″ (8.9 x 68.3 cm) |
3.5 x 40.7″ (8.9 x 103.4 cm) |
Controller Dimensions | 8.6 x 4.2 x 4″ (217.4 x 107.5 x 102 mm) | ||
Maximum Operating Pressure | 10.3 bar (150 psi) | ||
Operating Temperature Range | 2-65° C (36-149° F) | ||
UV Monitor | Upgradeable, includes visual glow plug | ||
Dry Contacts (solenoid ready) | Optional | ||
4-20 mA Output | Optional | ||
Lamp Age Counter | Yes | ||
Lamp-Out Indicator (audible & visual) | Yes | ||
Shipping Weight | 6.0 kg (13.2 lbs) | 7.2 kg (15.9 lbs) | 9.7 kg (21.4 lbs) |
TOC
Model | LBH5-151-TOC | LBH5-251-TOC | LBH5-401-TOC |
---|---|---|---|
Flow Rate 150 mJ/cm² @ 95% UVT (Industry Std.) |
3.0 gpm | 5.0 gpm | 8.5 gpm |
11 lpm | 19 lpm | 32 lpm | |
0.68 m³/hr | 1.1 m³/hr | 1.9 m³/hr | |
Port Size | 1″ MNPT | 1″ MNPT | 1½” MNPT |
Electrical | 90-265V / 50-60Hz | ||
Plug Type | American: Nema 5/15 – “1” suffix (i.e. LBH5-151-TOC) European: CEE 7/7 – “2” suffix (i.e. LBH5-152-TOC) British Standard: BS 1363 – “3” suffix (i.e. LBH5-153-TOC) Australian/New Zealand: AS/NZ 3112 – “4” suffix (i.e. LBH5-154-TOC) |
||
Lamp Watts | 45 | 67 | 101 |
Power (watts) | 57 | 73 | 115 |
Chamber Material | 316L Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated | ||
Replacement Lamp | RL-420HO-TOC | RL-600HO-TOC | RL-950HO-TOC |
Replacement Sleeve | RQ-420 | RQ-600 | RQ-950 |
Reactor Dimensions | 3.5 x 20.0″ (8.9 x 50.8 cm) |
3.5 x 26.9″ (8.9 x 68.3 cm) |
3.5 x 40.7″ (8.9 x 103.4 cm) |
Controller Dimensions | 8.6 x 4.2 x 4″ (217.4 x 107.5 x 102 mm) | ||
Maximum Operating Pressure | 10.3 bar (150 psi) | ||
Operating Temperature Range | 2-40° C (36-104° F) | ||
UV Monitor | Upgradeable, includes visual glow plug | ||
Dry Contacts (solenoid ready) | Optional | ||
4-20 mA Output | Optional | ||
Lamp Age Counter | Yes | ||
Lamp-Out Indicator (audible & visual) | Yes | ||
Shipping Weight | 6.0 kg (13.2 lbs) | 7.2 kg (15.9 lbs) | 9.7 kg (21.4 lbs) |